Sonde à ultrasons sectorielle Toshiba PSU-30BT 5S2, appareil médical
détail du produit

Autres sondes Toshiba que nous pouvons proposer :
| Marque | Modèle | Système compatible |
| Toshiba/Canon | PLF-805ST | SSA-340A et SSA-350A |
| Toshiba/Canon | PLM-1204AT | PowerVision 6000 SSA-370A/Nemio 17 SSA-550A/Xario SSA-660A |
| Toshiba/Canon | PLM-703AT | Powervision 6000 et Nemio |
| Toshiba/Canon | PLM-805AT | PowerVision 6000 SSA-370A/Némio 17 SSA-550A |
| Toshiba/Canon | PLT-1005BT | Aplio 300/ Aplio 400/ Aplio 500 |
| Toshiba/Canon | PLT-1204AT | Série Aplio 50 SSA-700A/ Aplio SSA-750A/ Xario |
| Toshiba/Canon | PLT-604AT | Série Xario / Aplio 50 SSA-700A / Aplio SSA-750A |
| Toshiba/Canon | PLT-704AT | Aplio 50 SSA-700A/ SSA-750A/ Xario |
| Toshiba/Canon | PLT-704SBT | Xario SSA-660A |
| Toshiba/Canon | PLT-805AT | SSA-700A/Aplio SSA-750A/Aplio SSA-770A/Xario SSA-660A |
| Toshiba/Canon | PLU-1204BT | Xario 100/Xario 200 |
| Toshiba/Canon | PSM-25AT | PowerVision 6000 SSA-370A/Némio 17 SSA-550A |
| Toshiba/Canon | PSM-37CT | PowerVision 6000 SSA-370A/Némio 17 SSA-550A |
| Toshiba/Canon | PST-25ST | Je t'aime |
| Toshiba/Canon | PST-30BT | Séries Xario et Aplio |
| Toshiba/Canon | PST-30BT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Artida SSH-880CV/ Xario SSA-660A |
| Toshiba/Canon | Bloc d'alimentation PSU-25BT (5S1) | Xario 100/Xario 200 |
| Toshiba/Canon | Bloc d'alimentation PSU-30BT (5S2) | Xario 100/Xario 200 |
| Toshiba/Canon | PVE-382M | 77B/90A/100A/240A/250A/TOSBEE |
| Toshiba/Canon | PVF-375MT | SSH-140A/ SSA-270A/ SSA-340A |
| Toshiba/Canon | PVM-375AT | PV 6000 SSA-370A/Némio 17 SSA-550A/Némio XG SSA-580A/Némio 30/SSA-370A |
| Toshiba/Canon | PVM-621VT | PowerVision 6000 SSA-370A/Némio 17 SSA-550A |
| Toshiba/Canon | PVM-651VT | PowerVision 6000 SSA-370A/Némio 17 SSA-550A |
| Toshiba/Canon | PVT-375BT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Aplio SSA-770A/ Aplio XG SSA-790A/ Xario SSA-660A/ SSA-680A |
| Toshiba/Canon | PVT-375BT | SSA-700A/SSA-750A/Aplio SSA-770A/SSA-790A/SSA-660A/SSA-680A |
| Toshiba/Canon | PVT-382BT | Aplio XG/Aplio MX/Xario XG/Xario/Viamo (2.0 et supérieur)/Aplio 500/Aplio 300 |
| Toshiba/Canon | PVT-575MV | Xario SSA-660A/ Aplio XG |
| Toshiba/Canon | PVT-661VT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Xario SSA-660A |
| Toshiba/Canon | PVT-661VT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Xario SSA-660A |
| Toshiba/Canon | PVT-674BT | Aplio 50 SSA-700A/Aplio SSA-750A |
| Toshiba/Canon | PVT-675MV | Xario 100/ Xario 200/ Aplio MX |
| Toshiba/Canon | PVT-681MV | Aplio 300/ Aplio 400/ Aplio 500/ Xario XG |
| Toshiba/Canon | PVT-712BT | Série Aplio/Série Xario |
| Toshiba/Canon | PVU-781VT | Xario |
Point de connaissance
Imagerie harmonique
L'imagerie harmonique exploite la propagation non linéaire des ultrasons à travers les tissus corporels. Lorsque la fréquence de l'onde sonore émise est f 0, la fréquence de l'écho (due à la réflexion ou à la diffusion) comprend f 0 (appelée onde fondamentale), 2f 0, 3F 0, etc. La deuxième harmonique (2f 0) possède la plus grande énergie.
L'imagerie harmonique ultrasonore (IHU) repose sur l'information du corps humain véhiculée par la seconde harmonique en écho (réflexion ou diffusion). L'imagerie harmonique sans UCA est appelée imagerie harmonique native ou imagerie harmonique tissulaire. L'imagerie harmonique utilisant l'UCA (agent de contraste ultrasonore) est appelée imagerie harmonique de contraste.