Toshiba PLT-1204BT Linear Ultrasound Transducer Diagnostic

1. Type:linear
2. Frequency: 7.2-14MHz
3. Compatible system: Xario 100/200
4. Application:Vascular, Small parts
5. Condition: new original
6. With 90 days warranty

 

    Other Toshiba probes we can offer:

    Brand Model Compatible System
    Toshiba/Canon PLF-805ST SSA-340A&SSA-350A
    Toshiba/Canon PLM-1204AT PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A/ Xario SSA-660A
    Toshiba/Canon PLM-703AT Powervision 6000 and Nemio
    Toshiba/Canon PLM-805AT PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A
    Toshiba/Canon PLT-1005BT Aplio 300/ Aplio 400/ Aplio 500
    Toshiba/Canon PLT-1204AT Aplio 50 SSA-700A/ Aplio SSA-750A/ Xario Series
    Toshiba/Canon PLT-604AT Xario Series / Aplio 50 SSA-700A/ Aplio SSA-750A
    Toshiba/Canon PLT-704AT Aplio 50 SSA-700A/ SSA-750A/ Xario
    Toshiba/Canon PLT-704SBT Xario SSA-660A
    Toshiba/Canon PLT-805AT SSA-700A/ Aplio SSA-750A/ Aplio SSA-770A/ Xario SSA-660A
    Toshiba/Canon PLU-1204BT Xario 100/Xario 200
    Toshiba/Canon PSM-25AT PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A
    Toshiba/Canon PSM-37CT PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A
    Toshiba/Canon PST-25ST Viamo
    Toshiba/Canon PST-30BT Xario & Aplio Series
    Toshiba/Canon PST-30BT Aplio 50 SSA-700A/ Aplio SSA-750A/ Artida SSH-880CV/ Xario SSA-660A
    Toshiba/Canon PSU-25BT(5S1) Xario 100/ Xario 200
    Toshiba/Canon PSU-30BT(5S2) Xario 100/ Xario 200
    Toshiba/Canon PVE-382M 77B/90A/100A/240A/250A/TOSBEE
    Toshiba/Canon PVF-375MT SSH-140A/ SSA-270A/ SSA-340A
    Toshiba/Canon PVM-375AT PV 6000 SSA-370A/ Nemio 17 SSA-550A/ Nemio XG SSA-580A/ Nemio 30/ SSA-370A
    Toshiba/Canon PVM-621VT PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A
    Toshiba/Canon PVM-651VT PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A
    Toshiba/Canon PVT-375BT Aplio 50 SSA-700A/ Aplio SSA-750A/ Aplio SSA-770A/ Aplio XG SSA-790A/ Xario SSA-660A/ SSA-680A
    Toshiba/Canon PVT-375BT SSA-700A/SSA-750A/ Aplio SSA-770A/SSA-790A/SSA-660A/ SSA-680A
    Toshiba/Canon PVT-382BT Aplio XG/Aplio MX/Xario XG/Xario/Viamo (2.0 and above)/Aplio 500/Aplio 300
    Toshiba/Canon PVT-575MV Xario SSA-660A/ Aplio XG
    Toshiba/Canon PVT-661VT Aplio 50 SSA-700A/ Aplio SSA-750A/ Xario SSA-660A
    Toshiba/Canon PVT-661VT Aplio 50 SSA-700A/ Aplio SSA-750A/ Xario SSA-660A
    Toshiba/Canon PVT-674BT Aplio 50 SSA-700A/ Aplio SSA-750A
    Toshiba/Canon PVT-675MV Xario 100/ Xario 200/ Aplio MX
    Toshiba/Canon PVT-681MV Aplio 300/ Aplio 400/ Aplio 500/ Xario XG
    Toshiba/Canon PVT-712BT Aplio series/ Xario series
    Toshiba/Canon PVU-781VT Xario

     

    Knowledge point

    Color Doppler flow imaging

    Color Doppler flow imaging system can simultaneously display B-type image and Doppler blood flow data (blood flow direction, flow velocity, flow dispersion) of dual ultrasound scanning system. Color power angio(CPA) detected the backscattered energy of blood cells in the blood flow, which did not distinguish the flow direction, and had nothing to do with the angle θ (the angle between the direction of sound wave and the direction of blood flow). CPA can improve the sensitivity of blood flow detection, especially suitable for displaying low-speed blood flow of small vessels, but can not show the direction of blood flow.