Leave Your Message

Aloka Alpha 6 EP555501AA Ultrasound Spare Parts Beamformer

1. Part Number: EP555501AA
2. Condition: Original and used,in good working condition
2. Lead Time: 2-4 days
3. Warranty :60 days

     

    Other Hitachi ultrasonic board we can exchange/offer.

     

    Brand  system Description Part number
    Aloka Alpha 5 mainboard EP493700DD
    Aloka Alpha 6 RX Beam Former EP555501AA
    Aloka Alpha 6 CW board EP555700
    Aloka Alpha 6 CPU mainboard EP537000/EP563000
    Aloka Alpha 6 TX/RX EP555300
    Aloka Alpha 6/Alpha 7 DOM EP550000AA
    Aloka Alpha 7 RX Beam Former EP539100BB/EP539500DG/EP539501DG
    Aloka Alpha 7 CPU mainboard EP558900
    Aloka Alpha 7 TI Board EP539000
    Aloka Alpha 7 TX board EP548300BB
    Aloka Alpha 7 touch screen L-Key-93H
    Aloka Alpha 10 RX Beamformer board EP531800CE
    Aloka Alpha 10 wave generator Board EP495000HH/EP495000HJ/EP495000FF
    Aloka Alpha 10 High-voltage Board EP541800
    Aloka Alpha 10 CPU mainboard EP496000
    Hitachi F31 RX Beamformer board EP568900
    Hitachi F31 mainboard EP575700BC/EP560800
    Hitachi F37 TX/RS EP557400/EP557300
    Hitachi F37 mainboard EP575700BC/EP560800
    Hitachi F37 BF Beamformer board EP557400
    Hitachi F37 RX mainboard EP557500
    Aloka F75 CONT-B EP556700BB
    Aloka F75 USP board EP556600
    Aloka F75 Cell Board EP558800
    Hitachi HI VISION Avius RDBF board 7513907A/7513612
    Hitachi HI VISION Avius CONT-B 7513734A
    Hitachi HI VISION Avius/Preirus Cell board 7345930A
    Hitachi HI VISION Preirus RX Board CZH4AA
    Hitachi HI VISION Preirus TX Board 7513629A
    Hitachi HI VISION Preirus CONT-B 7513640A/CZ84AJ
    Hitachi Arietta 60 TX  
    Hitachi Arietta 60 RX  
    Hitachi Arietta 60 CELL EU-9160C
    Hitachi Arietta 70 TX EP572300AA
    Hitachi Arietta 70 RX EP572900/EP572200
    Hitachi Arietta 70 CELL  
    Hitachi Noblus CELL  
    Hitachi Noblus CONT-B  
    Hitachi Ascendus TX  
    Hitachi Ascendus CELL 7352830A

     

     

     

    Knowledge point

     

    Common failures of color Doppler ultrasound

     

    1. Control panel failure

    2. System software, application software failure

    3. Back end failure

    4. Power failure (Main power supply, Low-voltage power supply, High-voltage power supply)

    5. Transducer Probe failure

    6. Front-end failure (Interface board, Transmitter, Receiver, Control, VIDEO, Front-end connection)

    7. Display failure (Display, Workstation, Touch screen)

    8. Failure caused by external environment